Ventis Pro5, Portable Multi-Gas Detector (VOC, O2, CO, H2S, LEL-CH4) ISC
Ventis Pro5 offers sensor and configuration options for numerous industries and applications, including standard and non-standard 4-gas, 5-gas, and a methane IR sensor, making it a cost-effective option for personal protection and confined space applications.
Detectable Gases: LEL (CH4% Vol), LEL (Methane), LEL (Pentane), O2, H2S, Cl2, CO, CO/H2 Low, CO/H2S, SO2, NO2, IR-CH4, IR-CO2 IR, CO2/CH4, IR-CO2/LEL, IR-HC, HCN, NH3, PH3
With the robust and wireless Ventis® Pro5 Multi-Gas Monitor, detect up to five gases simultaneously. Whether you need team-based alarm sharing, remote monitoring with location details, or both, the Ventis Pro5 meets all your gas monitoring management needs.
This device is designed to accurately measure a variety of gases. Below are the gases it can detect, their measurement ranges, resolutions, and the sensor technologies used:
- Flammable Gases (LEL): Measured in the 0-100% LEL range with a resolution of 1% using catalytic sensor technology.
- Methane (CH4): Detected in the 0-5% vol. range with a resolution of 0.01% using a catalytic sensor.
- Ammonia (NH3): Measured in the 0-500 ppm range with a resolution of 1 ppm using an electrochemical sensor.
- Carbon Monoxide (CO): Measured in the 0-2000 ppm range with a resolution of 1 ppm using an electrochemical sensor.
- Carbon Monoxide/Hydrogen Sulfide (COSH):
- CO: 0-1500 ppm range, 1 ppm resolution.
- H2S: 0-500 ppm range, 0.1 ppm resolution.
Both gases are detected using an electrochemical sensor.
- Chlorine (Cl2): Measured in the 0-50 ppm range with a resolution of 0.1 ppm using an electrochemical sensor.
- Hydrogen Sulfide (H2S): Measured in the 0-500 ppm range with a resolution of 0.1 ppm using an electrochemical sensor.
- Hydrogen Cyanide (HCN): Measured in the 0-30 ppm range with a resolution of 0.1 ppm using an electrochemical sensor.
- Nitrogen Dioxide (NO2): Measured in the 0-150 ppm range with a resolution of 0.1 ppm using an electrochemical sensor.
- Oxygen (O2): Measured in the 0-30% vol. range with a resolution of 0.1% using an electrochemical sensor.
- Phosphine (PH3): Measured in the 0-10 ppm range with a resolution of 0.01 ppm using an electrochemical sensor.
- Sulfur Dioxide (SO2): Measured in the 0-150 ppm range with a resolution of 0.1 ppm using an electrochemical sensor.
- Carbon Dioxide (CO2):
- Measured in the 0-5% vol. range with a resolution of 0.01% using an infrared sensor.
- Measured in the 0-5% vol. and 0-100% LEL ranges with resolutions of 0.01% and 1%, respectively, using an infrared sensor.
- Methane (CH4):
- Detected in the 0-5% vol. range with a resolution of 0.01% using an infrared sensor.
- Detected in the 0-100% vol. range with a resolution of 0.1% using an infrared sensor.